Product Details:
|
Usage: | High And Low Temperature Thermal Shock Test Chamber | Low Temp. Exposure Range*1: | -65to 0 °C |
---|---|---|---|
Temp. Heat Up Time*3: | Ambient Temp. To +200°C Within 30min | Temp. Pull Down Time*3: | Ambient Temp. To -65°C Within 70min |
Cooler: | Stainless Steel Welded Plate Heat Exchanger | Allowable Ambient Conditions: | +5~30°C |
Power Supply: | AC380V, 50/60Hz, Three Phase , 30A | Cooling Water Supply Pressure*6: | 02~0.4Mpa |
Cooling Water Supply Rate*6: | 8m³ /h | Operating Cooling Water Temp. Range: | +18 To 23 °C |
High Light: | environmental testing equipment,environmental lab testing equipment |
Small Environmental Thermal Shock Chamber For Electronics , Chemistry
1. Description:
Programmable Hot and Cold Temperature Shock Simulate Test Chamber is applied to industries such as electronics , chemistry, plastics ,metal and food for products to do reaction change test or breakdown test under the condition of high and low temperature rapid change. It includes preheat box, test box and precool box in structure .the specimen should be still put in the test box, and 2-box or 3-box test fuction can be choosed.
2. Specifications of Hot and Cold Temperature Shock Simulate Test Chamber:
System |
Two-zone test by means of damper switching |
|||||||
Three-zone chamber |
||||||||
Model |
HD-E703-50A/HD-E703-50W |
HD-E703-100A/HD-E703-100W |
Customized |
|||||
Performance |
Test area |
High temp. exposure range*1 |
+60~ to +200°C |
|||||
Low temp. exposure range*1 |
-65to 0 °C |
|||||||
Temp. fluctuation *2 |
±1.8°C |
|||||||
Hot chamber |
Pre-heat upper limit |
+200°C |
||||||
Temp. heat up time*3 |
Ambient temp. to +200°C within 30min |
|||||||
Cold chamber |
Pre-cool lower limit |
-65°C |
||||||
Temp. pull down time*3 |
Ambient temp. to -65°C within 70min |
|||||||
Temp. recovery (2-zone) |
Recovery conditions |
Two-zone: High temp. exposure +125°C 30 min, Low temp. exposure -40°C 30 min; Specimen 6.5 kg (specimen basket 1.5kg) |
||||||
Temp. recovery time |
Within 10 min. |
|||||||
Construction |
External material |
Cold-rolled rust-proofed steel plate |
||||||
Test area material |
SUS304 stainless steel |
|||||||
Door*4 |
Manually operated door with unlock button |
|||||||
Heater |
Strip wire heater |
|||||||
Refrigeration unit |
System*5 |
Mechanical cascade refrigeration system |
||||||
Compressor |
Hermetically sealed scroll compressor |
|||||||
Expansion mechanism |
Electronic expansion valve |
|||||||
Refrigerant |
High temp side:R404A, Low temp side R23 |
|||||||
Cooler |
Stainless steel welded plate heat exchanger |
|||||||
Air circulator |
Sirocco fan |
|||||||
Damper driving unit |
Air cylinder |
|||||||
Fittings |
Cable port with diameter 100mm on the left side (right side and tailor made diameter size are available as options), specimen power supply control terminal |
|||||||
Inside dimensions (W x H x D) |
350 x 400 x 350 |
500 x 450 x 450 |
Customized |
|||||
Test area capacity |
50L |
100L |
Customized |
|||||
Test area load |
5 kg |
10 kg |
Customized |
|||||
Outside dimensions (W x H x D) |
1230 x 1830 x 1270 |
1380 x 1980 x 1370 |
Customized |
|||||
Weight |
800kg |
1100kg |
N/A |
|||||
Utility requirements
|
Allowable ambient conditions |
+5~30°C |
||||||
Power supply |
AC380V, 50/60Hz, three phase , 30A |
|||||||
Cooling water supply pressure*6 |
02~0.4Mpa |
|||||||
Cooling water supply rate*6 |
8m³ /h |
|||||||
Operating cooling water temp. range |
+18 to 23 °C |
|||||||
Noise Level |
70 dB or lower |
Notes
1. If the high-temp exposure range lower limit + 60°C is required or the low temp exposure range lower limit -60°C, please select the “ambient-temperature exposure” option
2. If the temp fluctuation need to below ±1.8°C please select the “Low temp fluctuation package”
3. Temperature heat-up/pull down time are applicable only during independent chamber operation
4. If the automatically operated sliding door required, please select the “Automatically door package”
5. Air-cooled condenser / Water-cooled condenser both available
6. Apply on water-cooled condenser only
3. Safety Devices of Hot and Cold Temperature Shock Simulate Test Chamber:
Control
(Color LCD interactive touch-screen system)
Operation and settings simplified by the use of a touch-screen LCD display (instructions displayed on-screen). At-aglance confirmation of test patterns, test area temperatures, temperature cycles, and trend graph displays.
Setting |
Interactive key input by touch panel |
Display |
LCD (5.7 inches) |
Temperature control function |
Test area: exposure temp. Hot chamber: pre-heating temp. Cold chamber: pre-cooling temp. |
PID control |
|
Preset temperature range |
High temperature: 60 to200’C Low temperature: -78 to 0’C |
Setting resolution |
1’C |
Input |
Thermocouple type T (Copper/Copper-Nickel) |
Setting and indication ranges |
Preset time: 0 min. to 99 hours and 59 min. Preset cycle: 1 to 9,999 cycles |
Accessory function |
Timer preset Overheat/ overcool protection Power failure/ recovery selection Temperature recovery time setting Program memory Automatic power shut-off Programmed time display Test completion mode selection Trend graph Alarm history display Sensor calibration RS-232/ USB communication |