Product Details:
|
Interior Size (WxDxH): | 250x250x250mm | Certificate: | ISO, CE Etc |
---|---|---|---|
Temp. (optional): | Room Temp.~200°C Or 300°C | Electrothermal Tube: | 3 KW |
Weight: | 250kg | Power: | 1#, AC 220V/14.5A |
High Light: | ozone test chamber,xenon test chamber |
ISO SS Environmental Test Chamber Plastic Ozone Aging Resistance
Introduce
ISO SS Environmental Aging Chamber Plastic Ozone Aging Resistance Equipment is mainly suitable for polymer materials and products (rubber) of the resistance to ozone aging performance test. Ozone content in the atmosphere is very low,but it is the main factors of polymer materials aging. Ozone aging test chamber simulating and strengthen the ozone condition in the atmosphere, get approximate to actual use or reproduction of the test results in a short time. The studay of ozone effect regulation to rubber products, quickly identify and evaluate rubber materials resistance to ozone and antiozonant protection efficiency method,and then take effective aging proof measures to improve the service life of rubber products.
Applicable industries
Environmental ozone aging chamber supplier is widely used to control products quality in measuring quality control; Rubber & Plastics; automobile production; wire and cable; packing materials; instruments and meters; medical equipment; civilian nuclear energy; civil aviation; colleges and universities; research laboratories; inspection arbitration, and technical supervision departments and other rubber products.
Characteristics
Environmental ozone aging chamber by the occurrence of silent and efficient ozone generator ozone gas, and a certain amount of air processed, the switch in the mixture into the chamber, the continuous line UV detector to detect the concentration of ozone, ozone generator control feedback to the systems to control system settings according to the occurrence of effective control of ozone to the ozone chamber to maintain the appropriate concentration of work by heating humidification systems to meet all the test conditions.
Ozone Systems
As a result of the intermediate frequency high voltage power supply, due to the corona electrode does not produce heat, so that the concentration of ozone generated stable, will not change with the level of working hours or gas flow caused by the ozone concentration decreases. The high-frequency ceramic surface discharge corona generator due to the high frequency voltage discharge, when the temperature of the discharge region can not be effectively dissipated, leading to decomposition of ozone due to overheating, use under high flow conditions appropriate
With integrated ozone concentration ﹑ temperature and humidity controller (setting mode for the touch of a button type), high integration, good reliability, LED display, display resolution temperature (0.1 ℃), humidity (0.1% RH), the ozone concentration ( 1pphm), PID setpoint control, easy to operate
No wearing components, work maintenance-free, long life. The high-frequency ceramic surface discharge corona generator is easy to produce a ceramic electrode surface oxide deposits, when the surface oxide is too thick, prone to corona block, not cleaned, it will not produce ozone.
Operation Method
1. the timing of ozone aging test set
When you set through the "+" "on the timer panel -" button to set (H: hours, M: minute, S: seconds), for example, 2 hours and 30 minutes, set "02H30", set up after a good opening timer switch, press the power "ON" button, the device enters the high temperature thermostat is running, time, the device will automatically cut off the power.
2. ozone chamber ozone aging test start
Open the green power button. The chamber temperature to 40 degrees, and other chamber temperature to stabilize. Return 0 meter ozone, ozone, 20 minutes after the open button. Meter set to see the instrument instruction manual;
When the humidity test, Wuhan is still measured to remind you to check whether there is water inside the tank, dry water. Open the heat button. The test instrument adjusted to the required test temperature, open cooling button.
3. ozone aging chamber dynamic test:
Open the dial button and draw button, the necessary transfer speed, the exhaust button is at the end of the test and other ozone into the room open.
4. ozone aging chamber temperature alarm setting:
Press the key instrument to set "SET" 5 seconds to enter the inside of the instrument menu:
AL1 (Alarm 1): generally AL1 = SV + 15 ℃, when the high temperature alarm, low temperature need not be set. Example: SV is 50 ℃, the AL1 is 65 ℃.
ATU (Auto-tuning): Auto-tuning for the 0000 closed, 0001 is open. The machine is turned generally do not need self-tuning, if a constant set temperature value is difficult, open self-tuning. In the auto-tuning process, the inside temperature fluctuate is normal.
Technical parameter
Model |
HD-E801 ozone aging test chamber |
Ozone concentration |
5~200pphm (adjustable) 200~1000pphm(adjustable) |
Relative humidity |
No humidity, but can produce according to your requirement |
Temperature |
RT+10~+70°C |
Ozone produced mode |
Ozone generator or UV absorption method |
Inside air velocity |
over 2 feet/sec |
Degree of ozone concentration fluctuation |
10% |
Inside size |
500×500×600mm |
air flow |
A.0-6 cfm;B. 10-20 cfh |
weight |
250kg |
power |
1# ,AC220V,15A |
accessories |
tensile fixture 6 groups |
Corresponding standard
JIS K 6259 , ASTM1149 , ASTM1171, ISO1431, DIN53509 , GB/T13642, GB/T 7762-2003
GB 2951
Image:
Contact Person: Kelly