Product Details:
|
Usage: | Constant Temperature And Humidity Testing Machine | Temp. Range: | -70°C~150°C |
---|---|---|---|
Humid. Range: | 10~ 98 Percent R.H. | Temp. & Humid. Accuracy: | ± 0.3°C; ± 2 Percent R.H |
Temp. & Humid. Regularity: | ± 1°C; ± 3 Percent RH | Resolution: | 0.01°C, 0.1 Percent, P.I.D Control |
Insulation: | Rigid Foam | Display: | LCD |
Weight: | Approx. 600 Kg | Power: | AC220V±10 Percent 50/60Hz |
High Light: | Temperature And Humidity Controlled Cabinets,Constant Temperature And Humidity Chamber |
Humidity Testing Low And Empty Water Level Alarm Temperature Humidity Chamber
Temperature and humidity chamber.pdf
Download:Temperature and humidity chamber.pdf
Standard Features:
2. Specifications :
Range – 40 to 150°C
Temp/Humidity |
HD-E702-100-4 |
HD-E702-150-4 |
HD-E702-225-4 |
|
|
HD-E702-408-4 |
HD-E702-800-4 |
HD-E702-1000-4 |
|
Temp-only |
HD-E702-100T-4 |
HD-E702-150T-4 |
HD-E702-225T-4 |
|
|
HD-E702-408T-4 |
HD-E702-800T-4 |
HD-E702-1000T-4 |
|
Temperature Range: |
-40°C ~150°C |
|||
Cooling Capacity |
~ 2 kW at -20°C |
~ 2.5 kW at -20°C |
~ 4.5 kW at -20°C |
|
~ 5.5 kW at-20°C |
~ 8 kW at -20°C |
~ 8.5 kW at - -20°C |
||
Heating System |
~ 5 kW |
~ 5 kW |
~ 5.5 kW |
|
~6.5 kW |
~ 8.5 kW |
~ 9 kW |
||
Temperature Fluctuation: |
±0.5°C |
|||
Temperature Gradient: |
±0.5°C~±0.2°C |
|||
Heating Rate†: |
≥3℃ / min average ( Advance model 5 – 15 ℃ / min) |
|||
Cooling Rate†: |
≥1℃ / min average (Advance model 5 - 15℃ / min) |
|||
Humidity Range: |
10%~95%RH (Ref to Normal Humidity Range Diagramed) |
|||
Humidity Fluctuation: |
±1.5%RH~±2.0%RH |
|||
Humidity Gradient: |
±3%RH |
|||
Dimensions |
||||
Workspace dimensions |
500x400x500 HD-E702-100 |
600x500x500 HD-E702-150 |
750x500x600 HD-E702-225 |
|
|
850x650x800 HD-E702-800 |
1000x1000x800 HD-E702-800 |
1000x1000x1000 HD-E702-1000 |
|
Exterior dimensions |
1400x850x1050 |
1500x950x1050 |
1650x950x1150 |
|
|
1750x1050x1350 |
1900x1450x1350 |
1900x1450x1550 |
|
Site Requirements |
||||
Electrical Supply: |
208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) |
|||
Humidity Water |
Distilled Water |
|||
Condensate Drain: |
1/2" hose connection (gravity drain) |
Range – 70 to 150°C
Temp/Humidity |
HD-E702-100-7 |
HD-E702-150-7 |
HD-E702-225-7 |
|
|
HD-E702-408-7 |
HD-E702-800-7 |
HD-E702-1000-7 |
|
Temp-only |
HD-E702-100T-7 |
HD-E702-150T-7 |
HD-E702-225T-7 |
|
|
HD-E702-408T-7 |
HD-E702-800T-7 |
HD-E702-1000T-7 |
|
Temperature Range: |
-70°C ~150°C |
|||
Cooling Capacity |
~ 2.5 kW at -50°C |
~ 3 kW at -50°C |
~ 5 kW at -50°C |
|
~ 6.5 kW at-50°C |
~ 8.5 kW at -50°C |
~ 9 kW at - -50°C |
||
Heating System |
~ 5 kW |
~ 5 kW |
~ 5.5 kW |
|
~6.5 kW |
~ 8.5 kW |
~ 9 kW |
||
Temperature Fluctuation: |
±0.5°C |
|||
Temperature Gradient: |
±0.5°C~±0.2°C |
|||
Heating Rate†: |
≥3℃ / min average ( Advance model 5 – 15 ℃ / min) |
|||
Cooling Rate†: |
≥1℃ / min average (Advance model 5 - 15℃ / min) |
|||
Humidity Range: |
10%~95%RH (Ref to Normal Humidity Range Diagramed) |
|||
Humidity Fluctuation: |
±1.5%RH~±2.0%RH |
|||
Humidity Gradient: |
±3%RH |
|||
Dimensions |
||||
Workspace dimensions |
500x400x500 HD-E702-100 |
600x500x500 HD-E702-150 |
750x500x600 HD-E702-225 |
|
|
850x650x800 HD-E702-800 |
1000x1000x800 HD-E702-800 |
1000x1000x1000 HD-E702-1000 |
|
Exterior dimensions |
1400x850x1050 |
1500x950x1050 |
1650x950x1150 |
|
|
1750x1050x1350 |
1900x1450x1350 |
1900x1450x1550 |
|
Site Requirements |
||||
Electrical Supply: |
208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) |
|||
Humidity Water |
Distilled water |
|||
Condensate Drain: |
1/2" hose connection (gravity drain) |
3. Performance of Stability High Low Temperature and Humidity Test chamebr:
Get a performance evaluation to help provide the suitable chambers to you.
For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements.
Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.
System & Performance Options
(Normal Humidity Range Diagramed)
4. view:
(Advanced refrigeration design is especially compact for HD-Series Chambers)
Contact Person: Kelly
Fax: 86-0769-89280809